One client in Montebello, CA, called Pioneers Heating and Air for furnace repair service after detecting a burnt plastic smell from their unit. They also noted that the indoor temperature went down by about 5 degrees. The HVAC technician we sent to their home to diagnose the issue immediately noticed that the unit’s blower motor was fried and needed replacement. We ordered the replacement part immediately, and a few days later, the new blower arrived, and we installed it without issue. The client and technician were happy to eliminate the burnt-plastic smell!
HVAC systems are crucial for maintaining comfortable indoor temperatures, circulating fresh air, and providing ventilation. But when these systems break down, it can be a significant inconvenience—especially in the middle of extreme weather. Furnaces are particularly susceptible to issues, with blower motors being a common point of failure. So if you suspect your furnace’s blower motor is broken, it is crucial to get it checked out and potentially replaced as soon as possible.
The blower motor is one of the furnace’s most crucial components. This part is responsible for moving air around the burners in the combustion chamber, where it warms up. The heat exchanger subsequently disperses the hot air into the house’s ductwork. By pushing return air across the evaporator coil to be cooled and moved back into the house, the blower also contributes to the air conditioner’s operation. As a result, your heating and cooling system may experience serious issues if the blower motor experiences a malfunction.
Although blower motors can be durable, they may experience wear and tear over time. Common reasons for a blower motor to fail are overheating, excessive moisture, and being clogged with debris. When any of these things happen, it can cause the bearings and windings to burn out more quickly. Furthermore, furnaces are usually installed in areas that are not easily accessible, such as the attic, basement, or garage. Finally, if a blower motor becomes clogged with debris or saturated with moisture, it can fail due to overworking or an electrical short.
One of the first signs that your blower motor is having a problem is weak airflow from the vents. This issue may or may not mean that you need to replace the motor. Several potential causes for this issue include a clogged motor, leaky air ducts, or a bad capacitor. If the motor is overheating, damaged by moisture, or is nearing the end of its lifespan, then it will need to be replaced. A licensed HVAC technician can help you determine the problem and what needs to be done.
If there is no airflow from your vents when you turn on the heat, it could be due to several issues, such as a broken blower motor. In some cases, the only option would be to replace the motor blower. However, there could be other reasons for the lack of airflow, such as a bad relay or a faulty thermostat. So it is essential to troubleshoot the problem before taking any drastic measures.
If you notice your air vents emitting a burning smell whenever you run the heat, or if the system shuts down or the blower stops while in use, this may be a sign that the blower motor is overheating. In this case, it is best to call a licensed HVAC contractor as soon as possible to prevent further damage.
If you need furnace repair, there is no better company to trust than Pioneers Heating and Air. Our highly qualified specialists have years of expertise fixing all different types of furnaces, and we will work swiftly and effectively to get your furnace back up and running. Plus, we provide a range of heating and air conditioning services in addition to furnace repair so that we can always keep your house comfortable all year. We use top-of-the-line products, and our services come at reasonable costs to ensure that furnace repair service is not a significant burden on your wallet. Call us at (626) 217-0559 to arrange a no-cost consultation. We are eager to assist you wherever you are in Pasadena or the San Gabriel Valley!